Horizontal Distances
of Copper Links (Open Office)
The table entries assume that there is a total of 5m (16 ft.) of
patch and equipment cables in the telecommunications room. Table
1 shows the application of these formulae assuming the use of 24
AWG cable. The length of work area cables shall not exceed 22m (72
ft.) per TIA/EIA 568-B, 20m (66 ft.) per ISO/IEC 11801:2002. The
MuTOA shall be marked with the maximum allowable work area cable
length.
Table 1 ¡ª maximum length of work area cable
*Note:
The preceding equation and table are based on patch cables having
20% more attenuation than horizontal cables. If higher gauge (e.g.
26 AWG) cables are used that have 50% higher attenuation than
solid, as allowed by ISO/IEC 11801:2002, these lengths must be
reduced accordingly. |