Multi-Pair Cable
Performance markings should be provided to show the applicable
performance category. These markings do not replace safety markings.
Services with incompatible signal levels should be partitioned
into separate binder groups. Guidelines for shared sheaths are
provided in Annex B of '568-B.1.
Transmission requirements are equivalent to horizontal cables
except that hybrid requirements apply when multiple cable units
are contained within the same sheath.
Note: Tip conductors have colored insulation that corresponds
to that of the binder group. Ring conductors have colored insulation
that corresponds to that of the pair.
Backbone twisted-pair cables consist of solid 0.51mm (24 AWG)
cables that contain more than four pairs (typically multiples
of 25-pairs are used). An overall shield is optional.
Color-coding (specified by reference to ICEA: see chart below).
Color-Coding (Specified by Reference to ICEA)